{"id":897,"date":"2020-08-18T16:16:42","date_gmt":"2020-08-18T13:16:42","guid":{"rendered":"https:\/\/hipokrat.com.tr\/urun\/hipokrat-2000-knee-replacement-system\/"},"modified":"2021-06-23T16:02:18","modified_gmt":"2021-06-23T13:02:18","slug":"hipokrat-2000-knee-replacement-system","status":"publish","type":"product","link":"https:\/\/hipokrat.com.tr\/en\/urun\/hipokrat-2000-knee-replacement-system\/","title":{"rendered":"Hipokrat 2000 CR Knee Replacement System"},"content":{"rendered":"<div style=\"font-size: 14px; line-height: 25px; text-align: justify;\"><div class=\"jq-tabs tabs_wrapper tabs_\"><ul><li><a href=\"#tab-6a598da9407b5-1\">FEMORAL COMPONENT<\/a><\/li><li><a href=\"#tab-6a598da9407b5-2\">TIBIAL INSERT COMPONENT<\/a><\/li><li><a href=\"#tab-6a598da9407b5-3\">TIBIAL METAL BACK<\/a><\/li><li><a href=\"#tab-6a598da9407b5-4\">PATELLAR COMPONENT<\/a><\/li><\/ul><div id=\"tab-6a598da9407b5-1\" ><\/p>\n<p style=\"text-align: justify;\"><img style=\"float: right; clear: left; width: 300px; padding-left: 50px; padding-bottom: 30px;\" src=\"\/wp-content\/uploads\/2020\/08\/femoral-component-1.jpg\" \/>The femoral implant compresing of 3 sliding surfaces in contact with polyethelene, is a Cr.Co alloy who\u2019s reliability needs no further proof. The patellar groove is deeply hollowed and presents an anatomically aligned outline. This feature serves for better patellar guidance and relief of strain on the knee extensor apparatus. The femoral component is available in a cemented and a non-cemented version. A posterior stabilised version for more stabilisation is also available.<\/p>\n<p>\u2022 Anatomical 9 sizes femoral compenent offers optimal fit<br \/>\n\u2022 MRI safe Conditional option<br \/>\n\u2022 Cr.Co.Mo. alloy<br \/>\n\u2022 Rough inner surface provides strong cementation<br \/>\n\u2022 Cemented and Uncemented options<br \/>\n\u2022 Anatomic patellofemoral track<br \/>\n\u2022 Deep patella groove provides stable pattelofemoral tracking<br \/>\n\u2022 7 degree anterior flange<\/p>\n<p><\/div><div id=\"tab-6a598da9407b5-2\" ><\/p>\n<p style=\"text-align: justify;\"><img style=\"float: right; clear: left; width: 300px; padding-left: 50px; padding-bottom: 30px;\" src=\"\/wp-content\/uploads\/2020\/08\/tibial-component-text-1.jpg\" \/>The tibial insert of \u2018\u2018H\u0130POKRAT 2000 knee prosthesis\u2019\u2019 is an polyethelene high density .This choice is motivated by the excelent mechanical properties of this materials both in its strength and its tribological (low friction) qualities. This High density materials, proved for many years in the most reliable hip and knee prostheses, stil being unequalled today. It is here meticulously machined on specific dedicated machining centres, eliminating all risks of contamination. The tibial insert is available in 6 different heights of 6, 8, 10, 12, 15 and 18 mm so that the joint height can be restored depending on the degree of tibial bone substance loss. An ultracongruent and a posterior stabilised version for more stabilisation are also available.<\/p>\n<p>\u2022 Higher anterior surface will prevent the paradoxial anterior sliding<br \/>\n\u2022 Captured attachment screw<br \/>\n\u2022 5 Sizes, 6 thicknesses (6, 8, 10, 12, 15 and 18 mm)<br \/>\n\u2022 Anatomic radius<br \/>\n\u2022 UHMWPE pollyethelene<\/div><div id=\"tab-6a598da9407b5-3\" ><\/p>\n<p style=\"text-align: justify;\"><img style=\"float: right; clear: left; width: 300px; padding-left: 50px; padding-bottom: 30px;\" src=\"\/wp-content\/uploads\/2020\/08\/tibial-metal-back.jpg\" \/>The tibial plate has been designed in Cr.Co.Mo., and have rough inner surface to provides strong cementation. A locking screw which completely locks the tibial insert and ensures positive anchorage (without the slightest risk of the system being ejected). We add a final security. This locking screw is itself fitted with a locking mechanism.<\/p>\n<p>\u2022 9 sizes offers optimal fit<br \/>\n\u2022 MRI safe Conditional option<br \/>\n\u2022 Cr.Co.Mo. alloy<br \/>\n\u2022 Improved locking mechanism design<br \/>\n\u2022 Wings growing according to the size to ensure better stability.<\/div><div id=\"tab-6a598da9407b5-4\" >\n<p style=\"text-align: justify;\"><img style=\"float: right; clear: left; width: 300px; padding-left: 50px; padding-bottom: 30px;\" src=\"\/wp-content\/uploads\/2020\/08\/patellar-2.jpg\" \/>The patella is an polyethelene with offers the most ceratin contact and friction behaviour with the Cr.Co. trocchlea. Patellar implant is designed to help fill in lost patellar bone, restoring the patellofemoral joint space to its normal height.<\/p>\n<p>\u2022 Smooth anatomical design<br \/>\n\u2022 UHMWPE pollyethelene<br \/>\n\u2022 5 different diameter (31, 33, 35, 37 and 39 mm)<br \/>\n\u2022 Choice of one-peg and three-peg fixation modes are avaliable for increased flexibility<\/div><\/div><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<div style=\"padding: 30px 0 0 30px; border-left: solid 1px rgba(0,0,0,.08); border-top: solid 1px rgba(0,0,0,.08); border-radius: 30px 0 0 0;\">\n<div style=\"font-size: 12px;\">\n<div class=\"column one-third\"><a class=\"button  button_full_width button_size_3\" href=\"\/wp-content\/uploads\/2021\/06\/Hipokrat-2000-CR.pdf\" target=\"_blank\"   ><span class=\"button_label\">ORDERING INFORMATION<\/span><\/a>\n<\/div>\n\n<div class=\"column one-third\"><a class=\"button  button_full_width button_size_3\" href=\"\/wp-content\/uploads\/2020\/09\/hipokrat-2000-knee-replacement-system-1_compressed.pdf\" target=\"_blank\"   ><span class=\"button_label\">BROCHURE<\/span><\/a>\n<\/div>\n\n<div class=\"column one-third\"><a class=\"button  button_full_width button_size_3\" href=\"#\"    ><span class=\"button_label\">SURGICAL TECHNIQUE<\/span><\/a>\n<\/div>\n\n<\/div>\n<div style=\"font-size: 14px; line-height: 25px; text-align: justify;\">\n<p><b>Cruciate-Retaining Design<\/b><br \/>\nAs the name implies, the posterior cruciate ligament is kept with this implant design (the anterior cruciate ligament is removed). Cruciate-retaining implants do not have the center post and cam design. This implant may be appropriate for a patient whose posterior cruciate ligament is healthy enough to continue stabilizing the knee joint.<\/p>\n<p>Minimally constrained prosthesis that depends on an intact PCL to provide stability in flexion<\/p>\n<p><b>Indications<\/b><br \/>\n\u2022 Arthritis with minimal bone loss, minimal soft tissue laxity, and an intact PCL<br \/>\n\u2022 Varus deformity &lt; 10 degrees &#8211; valgus deformity &lt; 15 degrees<\/p>\n<p><b>Radiographs<\/b><br \/>\nRadiographs won&#8217;t show box in the central portion of the femoral component as PS knees have<\/p>\n<p><b>Advantages<\/b><br \/>\n\u2022 Avoids tibial post-cam impingement\/dislocation that may occur in PS knees<br \/>\n\u2022 More closely resembles normal knee kinematics<br \/>\n\u2022 Less distal femur needs to be cut than in a PS knee<br \/>\n\u2022 Improved proprioception with preservation of native PCL<br \/>\n\u2022 Newer poly-options can allow for PCL substitution via anterior-stabilized or ultra-congruent shapes in cases of PCL insufficiency without loss of functional results<\/p>\n<p><b>Disadvantages<\/b><br \/>\n\u2022 Tight PCL may cause accelerated polyethylene wear<br \/>\n\u2022 Loose or ruptured PCL may lead to flexion instability and subluxation<\/p>\n<\/div>\n<\/div>\n","protected":false},"featured_media":905,"template":"","meta":[],"product_cat":[58],"product_tag":[],"_links":{"self":[{"href":"https:\/\/hipokrat.com.tr\/en\/wp-json\/wp\/v2\/product\/897"}],"collection":[{"href":"https:\/\/hipokrat.com.tr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/hipokrat.com.tr\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hipokrat.com.tr\/en\/wp-json\/wp\/v2\/media\/905"}],"wp:attachment":[{"href":"https:\/\/hipokrat.com.tr\/en\/wp-json\/wp\/v2\/media?parent=897"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/hipokrat.com.tr\/en\/wp-json\/wp\/v2\/product_cat?post=897"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/hipokrat.com.tr\/en\/wp-json\/wp\/v2\/product_tag?post=897"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}