{"id":927,"date":"2020-08-28T14:02:43","date_gmt":"2020-08-28T11:02:44","guid":{"rendered":"https:\/\/hipokrat.com.tr\/?post_type=product&#038;p=927"},"modified":"2021-06-23T16:01:19","modified_gmt":"2021-06-23T13:01:19","slug":"hipokrat-2000-ps-knee-replacement-system","status":"publish","type":"product","link":"https:\/\/hipokrat.com.tr\/en\/urun\/hipokrat-2000-ps-knee-replacement-system\/","title":{"rendered":"Hipokrat 2000 PS Knee Replacement System"},"content":{"rendered":"<div style=\"font-size: 14px; line-height: 25px; text-align: justify;\"><div class=\"jq-tabs tabs_wrapper tabs_\"><ul><li><a href=\"#tab-6a598dbf45c85-1\">FEMORAL COMPONENT<\/a><\/li><li><a href=\"#tab-6a598dbf45c85-2\">TIBIAL INSERT COMPONENT<\/a><\/li><li><a href=\"#tab-6a598dbf45c85-3\">TIBIAL METAL BACK<\/a><\/li><li><a href=\"#tab-6a598dbf45c85-4\">PATELLAR COMPONENT<\/a><\/li><\/ul><div id=\"tab-6a598dbf45c85-1\" ><\/p>\n<p style=\"text-align: justify;\"><img style=\"float: right; clear: left; width: 300px; padding-left: 50px; padding-bottom: 30px;\" src=\"\/wp-content\/uploads\/2020\/08\/ps-femoral-component.jpg\" \/>The femoral implant compresing of 3 sliding surfaces in contact with polyethelene, is a Cr.Co alloy who\u2019s reliability needs no further proof. The patellar groove is deeply hollowed and presents an anatomically aligned outline. This feature serves for better patellar guidance and relief of strain on the knee extensor apparatus. The femoral component is available in a cemented and a non-cemented version. A cruciate retaining version is also available.<\/p>\n<p>\u2022 Anatomical 9 sizes femoral compenent offers optimal fit<br \/>\n\u2022 MRI safe Conditional option<br \/>\n\u2022 Cr.Co.Mo. alloy<br \/>\n\u2022 Rough inner surface provides strong cementation<br \/>\n\u2022 Cemented and Uncemented options<br \/>\n\u2022 Anatomic patellofemoral track<br \/>\n\u2022 Deep patella groove provides stable pattelofemoral tracking<br \/>\n\u2022 7 degree anterior flange<\/p>\n<p><\/div><div id=\"tab-6a598dbf45c85-2\" ><\/p>\n<p style=\"text-align: justify;\"><img style=\"float: right; clear: left; width: 300px; padding-left: 50px; padding-bottom: 30px;\" src=\"\/wp-content\/uploads\/2020\/08\/tibial-component-text-ps.jpg\" \/>The tibial insert of \u2018\u2018H\u0130POKRAT 2000 knee prosthesis\u2019\u2019 is an polyethelene high density .This choice is motivated by the excelent mechanical properties of this materials both in its strength and its tribological (low friction) qualities. This High density materials, proved for many years in the most reliable hip and knee prostheses, stil being unequalled today. It is here meticulously machined on specific dedicated machining centres, eliminating all risks of contamination. The tibial insert is available in 6 different heights of 6, 8, 10, 12, 15 and 18 mm so that the joint height can be restored depending on the degree of tibial bone substance loss. An ultracongruent and a cruciate retaining version is also available.<\/p>\n<p>\u2022 Higher anterior surface will prevent the paradoxial anterior sliding<br \/>\n\u2022 Captured attachment screw<br \/>\n\u2022 5 Sizes, 6 thicknesses (6, 8, 10, 12, 15 and 18 mm)<br \/>\n\u2022 Anatomic radius<br \/>\n\u2022 UHMWPE pollyethelene<\/div><div id=\"tab-6a598dbf45c85-3\" ><\/p>\n<p style=\"text-align: justify;\"><img style=\"float: right; clear: left; width: 300px; padding-left: 50px; padding-bottom: 30px;\" src=\"\/wp-content\/uploads\/2020\/08\/tibial-metal-back.jpg\" \/>The tibial plate has been designed in Cr.Co.Mo., and have rough inner surface to provides strong cementation. A locking screw which completely locks the tibial insert and ensures positive anchorage (without the slightest risk of the system being ejected). We add a final security. This locking screw is itself fitted with a locking mechanism.<\/p>\n<p>\u2022 9 sizes offers optimal fit<br \/>\n\u2022 MRI safe Conditional option<br \/>\n\u2022 Cr.Co.Mo. alloy<br \/>\n\u2022 Improved locking mechanism design<br \/>\n\u2022 Wings growing according to the size to ensure better stability.<\/div><div id=\"tab-6a598dbf45c85-4\" >\n<p style=\"text-align: justify;\"><img style=\"float: right; clear: left; width: 300px; padding-left: 50px; padding-bottom: 30px;\" src=\"\/wp-content\/uploads\/2020\/08\/patellar-2.jpg\" \/>The patella is an polyethelene with offers the most ceratin contact and friction behaviour with the Cr.Co. trocchlea. Patellar implant is designed to help fill in lost patellar bone, restoring the patellofemoral joint space to its normal height.<\/p>\n<p>\u2022 Smooth anatomical design<br \/>\n\u2022 UHMWPE pollyethelene<br \/>\n\u2022 5 different diameter (31, 33, 35, 37 and 39 mm)<br \/>\n\u2022 Choice of one-peg and three-peg fixation modes are avaliable for increased flexibility<\/div><\/div><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<div style=\"padding: 30px 0 0 30px; border-left: solid 1px rgba(0,0,0,.08); border-top: solid 1px rgba(0,0,0,.08); border-radius: 30px 0 0 0;\">\n<div style=\"font-size: 12px;\">\n<div class=\"column one-third\"><a class=\"button  button_full_width button_size_3\" href=\"\/wp-content\/uploads\/2021\/06\/Hipokrat-2000-PS.pdf\" target=\"_blank\"   ><span class=\"button_label\">ORDERING INFORMATION<\/span><\/a>\n<\/div>\n\n<div class=\"column one-third\"><a class=\"button  button_full_width button_size_3\" href=\"\/wp-content\/uploads\/2020\/09\/hipokrat-2000-knee-replacement-system-1_compressed.pdf\" target=\"_blank\"   ><span class=\"button_label\">BROCHURE<\/span><\/a>\n<\/div>\n\n<div class=\"column one-third\"><a class=\"button  button_full_width button_size_3\" href=\"#\"    ><span class=\"button_label\">SURGICAL TECHNIQUE<\/span><\/a>\n<\/div>\n\n<\/div>\n<div style=\"font-size: 14px; line-height: 25px; text-align: justify;\">\n<p><b>Posterior-Stabilized Design<\/b><br \/>\nOne of the most commonly used type of implant in total knee replacement is a posterior-stabilized component. In this design, the cruciate ligaments are removed and parts of the implant substitute for the posterior cruciate ligament (PCL).<\/p>\n<p>The tibial component has a raised surface with an internal post that fits into a special bar (called a cam) in the femoral component. These components work together to do what the PCL does: prevent the thighbone from sliding forward too far on the shinbone when you bend your knee.<\/p>\n<p>\u2022 Slightly more constrained prosthesis that requires sacrifice of PCL<br \/>\n\u2022 Resection of PCL increases the flexion gap in relationship to extension gap so posterior must be matched to avoid flexion-extension mismatch<br \/>\n\u2022 Femoral component contains a cam that engages the tibial polyethylene post during flexion<br \/>\n\u2022 Polyethylene inserts are more congruent, or deeply \u201cdished\u201d<\/p>\n<p><b>Indications<\/b><br \/>\n\u2022 Previous patellectomy<br \/>\n\u2022 Reduces risk of potential anteroposterior instability in setting of a weak extensor mechanism<br \/>\n\u2022 Inflammatory arthritis<br \/>\n\u2022 Inflammatory arthritis may lead to late PCL rupture<br \/>\n\u2022 Deficient or absent PCL<\/p>\n<p><b>Radiographs<\/b><br \/>\nLateral radiograph will show the outline of the cam, or box, in the femoral component<\/p>\n<p><b>Advantages<\/b><br \/>\n\u2022 Easier to balance a knee with absent PCL<br \/>\n\u2022 Arguably more range of motion<br \/>\n\u2022 Easier surgical exposure<\/p>\n<p><b>Disadvantages<\/b><br \/>\n\u2022 Cam jump mechanism with loose flexion gap, or in hyperextension, the cam can rotate over the post and dislocate treatment initial closed reduction by performing an anterior drawer maneuver final revision to address loose flexion gap<br \/>\n\u2022 Tibial post polyethylene wear<br \/>\n\u2022 Patellar &#8220;clunk&#8221; syndrome mechanism scar tissue gets caught in box as knee moves into extension treatment arthroscopic versus open resection of scar tissue<br \/>\n\u2022 Additional bone is cut from distal femur to balance extension gap<\/p>\n<\/div>\n<\/div>\n","protected":false},"featured_media":935,"template":"","meta":[],"product_cat":[58],"product_tag":[],"_links":{"self":[{"href":"https:\/\/hipokrat.com.tr\/en\/wp-json\/wp\/v2\/product\/927"}],"collection":[{"href":"https:\/\/hipokrat.com.tr\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/hipokrat.com.tr\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hipokrat.com.tr\/en\/wp-json\/wp\/v2\/media\/935"}],"wp:attachment":[{"href":"https:\/\/hipokrat.com.tr\/en\/wp-json\/wp\/v2\/media?parent=927"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/hipokrat.com.tr\/en\/wp-json\/wp\/v2\/product_cat?post=927"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/hipokrat.com.tr\/en\/wp-json\/wp\/v2\/product_tag?post=927"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}